资讯内容

日本 Apiste服务器冷却器ENC-GR2000L-ECO

发布时间:2025年6月26日
阅读量:0

Specifications (50/60Hz) Mounting type Side-mounting Cooling capacity(W) 2000 Setting Temperature Range(℃) 25~45 Use Area Temperature(℃) 20~55 Use Area Humidity(%RH) 10~85 Specifications External dimensions(mm) H1200×W450×D230 Weight(kg) 44 Coating Color Munsell 5Y 7/1 Equivalent color of light beige Rated Voltage(V) Single-phase AC200~240 Consumption Current: Rated(A) 4.5/4.3 Consumption Current: MAX(A) 5.8/5.7 Consumption wattage: Rated(W) 725 Consumption wattage: MAX(W) 950 Recommended breaker capacity (A) 10 Vibration Resistance Equivalent to JIS Z 0200 Level1 Dust prevention / dust proof protection class Equivalent to IP54 (internal circulation route) Refrigerant / Fill ration(g) R1234yf 700g Noise (dB (A)) Approx. 73 External Output Alarm output (No-voltage/normal open: resistive load 250V 2A), Can be switched to no-voltage/normal close by setting Display Internal temperature/Error/RUN *Cooling Capacity : Rated capacity value when ambient temperat ure is 35°C and ambient humidity is 40%RH , power source & voltage : 200V. (Measuring specification :JIS B 8615-1 the inside of a air enthalpy test method) *Use area temperature / humidity : Use area temperature / humi dity is not meant to satisfy all conditions in temperature and humidity. *Rating Value : 35°C ambient temperature, ambient humidity RH 40%, power source & voltage : 200V. *Maximum Value : The ambient temperature at MAX value has spec ification separately. *Use the product keeping the use power supply and voltage; wit hin ±10% of rated power supply and rated voltage. *Consumption current and wattage are values during cooling ope ration. *Dust prevention / dust proof protection class : Excluding dra in pipe section *Reading an instruction manual well certainly before use and p lease use it right. External dimensions Diagram of Panel Cutout Capacity characteristic chart [Caution] To ensure proper operation of this equipment, read the operation manual before use. Depending on model and quantity, separate charter delivery may be arranged (additional costs apply). When delivering overseas, special packing for overseas shipment is recommended. After checking the specifications of the FA cooler, be sure to insert an appropriate breaker (circuit breaker for wiring) between the FA cooler and the power supply. Using beyond the rated power supply range may cause malfunction. Perform periodic maintenance. Neglecting periodic maintenance can degrade unit performance and cause mechanical problems. Do not allow the FA cooler to operate continuously in winter when the outdoor temperature is low. When disposing of this unit, do so properly in accordance with laws and regulation.

上一篇

日本东方马达K2系列交流电机4IK25UCT2-250S

2025-06-26 | 东方马达

下一篇

日本东方马达K2系列交流电机4IK25UCT2-25S

2025-06-26 | 东方马达

相关文章

联系我们

客服电话

13341246192

邮箱地址

sinfag@126.com

微信号

ahy_gl

微信二维码

微信二维码

扫码添加客服微信

工作时间

周一至周五:9:00-18:00

周六:9:00-17:00

节假日休息